COLOUR MATCHING CABINET
The “ASIAN” Colour Matching Cabinet provide standardized and environment for visual assessment of colour .it is suitable for all applications where is a need to maintain colour consistency and quality .it allow a person to evaluate colour sample under different light sources ,artificial daylight ,filament light ultra violet light and tube light TL 84 (triphosphor fluorescent light ) . The use of multiple light sources is the only way to detect metamerism when samples appear to match less than one light source is the only way to distinctly different under another.
Colour matching is universally preferred choice for faster, closer and accurate colour matching of samples.
TECHNICAL DATA
I) SWITCH IDENTIFICATION
S, NO |
SWITCH CODE |
INDICATEING |
1 |
MAINS |
MAINS ON /OFSWITCH .IT SHOULD BELEFT IN OFF. |
2 |
D-65 |
ARTIFICIAL DAY LIGHT FLUORESCENT LAMP FOR INITIAL COLOUR MATCHING |
3 |
TL- 84 |
TRIPHOSPHOR FLUORESCENT LIGHT AS OF TEN CHOSEN AS APOINT OF SALE ILLUMINANT |
4 |
CWF |
COOL WHITE LIGHT |
5 |
TUNGUSTEN |
TUNGUSTEN FILAMENT LIGHT AS TEST FOR DOMESTICLIGHT |
6 |
UV LIGHT |
ULTRA VIOLET BLACKLIGHT TO REVEAL THE PERSENCE OF FLURESCENT DYES AND BLEACHES. |
7 |
HOUR TOTELISER |
TIME ELAPSE HOUR METER TO INDICATE HOUR RUN OF THE TL –84 THE LAMP SHOULD BEREPLACED AFTER 2600 HOURS TO ENSURE CONFERMENCE TO BS :950 |
II) COLOUR TEMPERATURE (Approximately)
A.D.Light : 6500 K
TL-84 Light : 400 K
TUNGUSTAN FILAMENT : 2300 – 2800 K
U.V.Light : Ultra Violet